Remote meter reading: Germany’s end-2026 deadline
The general deadline for upgrading heating and hot-water metering equipment is the end of 2026. Review the obligations, exceptions and costs that may affect your rental property.
You let a flat, and once a year a meter reader calls. They record the readings from the radiators and the hot-water meter, and a few weeks later the bill arrives. Devices that cannot be read remotely are generally subject to a retrofit deadline.
Under the German Heating Costs Ordinance [Heizkostenverordnung; HeizkostenV], existing heat cost allocators, heat meters and hot-water meters that cannot be read remotely must generally be retrofitted or replaced by 31 December 2026 where the legislation applies. Statutory exceptions remain possible. Failing to meet an applicable obligation can give tenants a right to reduce their charges.
01What the Heating Costs Ordinance requires
The Ordinance applies particularly to buildings with communal heating or hot-water systems where several users share the costs. This can include rented blocks of flats and individually owned flats with communal systems. Its scope and exceptions must be assessed for each property. Building owners must generally record each user's share of consumption (section 4(1)).
Under section 5(2), a device is remotely readable if it can be read without entering the flat. Examples include wireless heat cost allocators and meters whose readings can be received outside the flat or transmitted to the metering provider.
| From or by | Requirement | Legal basis |
|---|---|---|
| December 2021 | Newly installed devices must generally be remotely readable, subject to statutory exceptions | Section 5(2), sentence 1 |
| December 2022 | New devices are subject to additional requirements for smart meter gateway connectivity and interoperability | Section 5(2), sentence 3, and section 5(5) |
| 1 January 2022 | Monthly consumption information for tenants where remotely readable devices are installed | Section 6a(1), point 2 |
| 31 December 2026 | Existing devices that cannot be read remotely must generally be retrofitted or replaced | Section 5(3) |
| 31 December 2031 | Transitional deadline for additional requirements applying to older remotely readable devices; check installation dates and statutory scope | Section 5(4) |
The requirement covers heat cost allocators on radiators, heat meters and hot-water meters. The Ordinance does not regulate cold-water meters. Other provisions apply to those, including legislation at German state level.
02Monthly consumption information
Remotely readable devices bring an additional obligation: you must provide tenants with monthly consumption information (section 6a(1), point 2). This information must include at least:
- the previous month's consumption in kilowatt-hours;
- a comparison with the preceding month and the same month in the previous year, where the relevant data have been collected;
- a comparison with a standardised average user, or one established through comparative testing, in the same user category (section 6a(2)).
A metering provider can handle this task. Possible delivery methods include an app, an online portal or email, but the specific arrangements must fulfil the information requirement. The costs may be recoverable as heating costs where the statutory and contractual conditions are met (section 7(2)).

03What happens if you miss the deadline
The Heating Costs Ordinance itself does not provide for a fine for this breach. One consequence concerns billing: if an owner has failed to install remotely readable devices contrary to section 5(2) or (3), a user can reduce their share of heating and hot-water charges by 3% (section 12(1), sentence 2). The Ordinance also provides a reduction right where information is not supplied, or is incomplete, contrary to section 6a (section 12(1), sentence 3).
However, the absence of remotely readable devices does not automatically create an additional breach of the monthly information requirement: that requirement generally depends on such devices being installed. This article therefore does not assume a blanket 6% reduction. Whether several reduction rights apply together in a particular case, and which billing period is affected, requires legal assessment. A continuing breach can also affect subsequent billing years.
04Buying or hiring the devices
Upgrade costs depend on whether you buy or hire the devices. The scope for recovering costs from tenants also differs.
| Buying | Hiring | |
|---|---|---|
| Recovery from tenants | Purchase costs are not recoverable as recurring heating costs; assess any other possible legal basis separately | May be recoverable as heating costs if statutory and contractual conditions are met (section 7(2)) |
| Meter reading and billing | Recoverable subject to the applicable conditions | Recoverable subject to the applicable conditions |
| Replacement following a fault or expiry of the statutory verification period | Generally the owner's cost; check warranty and service terms | Depends on the hire and service agreement |
| Tenants' involvement | The objection procedure for device hire under section 4(2) does not apply | A majority can object within one month of receiving the notice (section 4(2)) |
An owner intending to hire devices, or obtain their use under another arrangement, must notify users in advance and state the resulting costs. If a majority objects within one month of receiving the notice, the proposed arrangement is not permitted under section 4(2). Express approval by a majority is not a requirement of this procedure. Allow for the notice and objection period before placing an order.
- 01Check the existing equipment
Review the latest meter-reading record to establish which devices are installed, when they were fitted and whether they can be read remotely. A previous visit by a meter reader does not, on its own, prove that remote reading is unavailable.
- 02Obtain quotations
Ask at least two metering providers about purchase and hire prices, contract terms, gateway connectivity, interoperability and monthly consumption information.
- 03Notify tenants
For device hire, send the notice stating the costs and allow the one-month objection period from receipt.
- 04Schedule installation
Replacing devices will usually require access to the affected flats. Give appropriate advance notice of the appointment.
- 05Update billing arrangements
If devices are replaced during a billing year, clarify the interim readings and records required. Check that both old and new readings are correctly reflected in the next bill.
05Worked example: upgrading or facing reductions
In this fictional example, Peter Hoffmann owns a building containing six rented flats, with communal gas heating and annual heating and hot-water charges totalling €7,200 payable by tenants. Each flat has four old evaporation-based heat cost allocators and one mechanical hot-water meter. The name is fictional, and the figures are an illustration, not a forecast. All prices are assumptions.
The comparison assumes that no exception to the upgrade requirement applies, that the breach affects a full billing year and that all tenants exercise a 3% reduction right on the total of €7,200. The assumed purchase cost is €1,440 including installation. The hire option assumes no separate upfront payment and full, valid recovery of the annual device hire charge from tenants. Additional service, information and financing costs, or differences in those costs between the options, have not been quantified and are excluded.
| Buy | Hire | Take no action | |
|---|---|---|---|
| 24 wireless heat cost allocators, 6 hot-water meters, installation | −€1,440 once | €0 separate upfront payment assumed | €0 |
| Annual device hire, after full recovery from tenants | €0 | €0 net from €282 in costs and €282 recovered | €0 |
| Annual reduction claimed by tenants, 3% of €7,200 | €0 | €0 | −€216 |
| First-year cost before tax | −€1,440 | €0 | −€216 |
| Tax effect | not established | not established | not established |
| First-year cost after tax | not established | not established | not established |
Under these simplified assumptions, the cumulative reduction initially remains below the purchase price. A purchase cost of €1,440 equates to approximately 6.7 annual reductions of €216; measured in complete years, cumulative reductions exceed the assumed purchase price in year seven. This is neither a lawful alternative to compliance nor a complete financial comparison. Further costs, changes in heating charges and possible disputes are excluded.
Under the assumptions used, none of the device hire charge remains with the landlord. The €282 equates to an average of €47 per flat per year. Actual allocation follows the applicable billing formula and need not be equal for every flat. The statutory procedure requires advance notice of the costs and allows a majority to object within one month; it does not require express majority approval.

06An individually owned flat: the association must act
For a rented, individually owned flat, equipment provision generally needs to be organised at owners' association level. Selection, installation and cost allocation are governed by German condominium ownership law (section 3 of the Heating Costs Ordinance). Whether an upgrade has already been completed must be established from the equipment and records.
Check the latest owners' meeting minutes and metering contracts. If you cannot find a resolution approving a necessary upgrade, contact the managing agent. Establish whether a valid resolution already exists, a meeting is needed or a resolution by circulation [Umlaufbeschluss] is possible under the applicable conditions. Both decision-making and implementation can take time.
07Who needs to act now
- Your flat has evaporation tubes or devices confirmed as not remotely readable.
- Despite remotely readable devices being installed, your tenant receives no monthly consumption information.
- A necessary upgrade has not been approved or commissioned by the owners' association.
- The devices are confirmed as remotely readable; further technical requirements still need checking.
- The metering provider properly supplies the required monthly information, for example through an app or portal with suitable notifications.
- Each flat has its own gas boiler and its occupier pays the supplier directly for consumption; any communal hot-water system requires separate assessment.
08Risks and outstanding points
Possible year-end capacity constraints. If metering providers or installers are fully booked, securing an appointment before the deadline may be difficult. Ask about actual availability early.
Further requirements by 2031. Older remotely readable devices may be subject to additional requirements by the end of 2031 (section 5(4)). Check installation dates, gateway connectivity and interoperability. Replacement is not necessarily required if devices already comply or can be suitably upgraded.
Long contracts. Meter hire agreements can involve long commitments, such as ten years. Check the term, price adjustment clauses and included services before signing. Section 5(5) contains requirements on interoperability and the free provision of the necessary cryptographic key material. Establish how another metering provider could take over the devices in practice.
Billing errors. An applicable reduction right can lead to challenges to the bill. Establish the calculation basis and affected period rather than applying a percentage indiscriminately.
FAQFrequently asked questions
When must meters be remotely readable?
Heat cost allocators, heat meters and hot-water meters that cannot be read remotely generally need to be retrofitted or replaced by 31 December 2026 where the German Heating Costs Ordinance [Heizkostenverordnung] applies (section 5(3)). New devices have generally been subject to remote-reading requirements since December 2021. Statutory exceptions and transitional provisions must be considered.
Does the requirement cover cold-water meters?
No. The Heating Costs Ordinance covers heating and hot water, not cold-water meters. Other provisions apply to cold-water meters; the end-2026 upgrade deadline discussed here does not cover them.
What happens if I do not upgrade?
The Heating Costs Ordinance itself does not provide for a fine for this breach. If the remote-reading requirement is breached, a tenant can reduce their share of heating and hot-water charges by 3% (section 12(1)). A continuing breach can affect further billing years. An additional reduction for missing monthly information does not follow automatically.
Must I provide tenants with monthly consumption information?
Where remotely readable devices are installed, a monthly information requirement generally applies (section 6a). It includes the previous month's consumption in kilowatt-hours, comparisons with the preceding month and the same month a year earlier where those data have been collected, and a comparison with an appropriate average user in the same category. Breaching this obligation can trigger a 3% reduction right.
Can I pass wireless metering costs on to tenants?
Device hire, meter reading, billing and consumption information may be recoverable if the statutory and contractual conditions are met (section 7(2)). Purchase costs are not recurring heating costs. Before hiring devices, users must be informed of the proposal and its costs. If a majority objects within one month of receiving the notice, the arrangement is not permitted (section 4(2)); express majority approval is not required.
Who is responsible for an individually owned flat?
Equipment provision generally needs to be organised through the owners' association and managing agent (section 3 of the Heating Costs Ordinance). Your tenant's reduction right is exercised against you as landlord, not against the association. It does not give you an equivalent right to reduce your building service charge. Any further claims require separate assessment.
Does the requirement also apply to heat pumps?
Buildings supplied by communal heat pumps can also fall within the Heating Costs Ordinance. Section 12(3) contains a transitional provision with a deadline at the end of September 2025. Whether consumption metering is required, and in what form, depends on the supply system, statutory scope and possible exceptions. Newly installed consumption metering devices are generally subject to remote-reading requirements.
09Further reading
- Heating cost statements for landlords
- Operating cost statements for landlords
- Checking service charge statements
- Reviewing owners' meeting minutes
- Glossary: resolutions by circulation
- Glossary: rent including service charges
10Sources
- German Heating Costs Ordinance, sections 3, 4, 5, 6a, 7, 11 and 12; amendment: Article 3 of the Act of 16 October 2023 (BGBl. 2023 I No. 280)
- Worked example: calculation with disclosed assumptions
Note: This guide provides general information and does not replace individual legal or tax advice. All illustrative prices are assumptions.

Writes about Investment properties, New builds and renovation and Financing.
Nadeem is a qualified insurance and finance merchant, spent around eight years self-employed in the insurance and finance industry and has specialised in investment property since 2024. He writes about new builds, renovation, financing and the running costs of rented property.
This guide does not replace tax or legal advice. All figures are example calculations with disclosed assumptions.